BWZTS - ELECTROSTATIC 867 CLEANING FLUID, MASTER IMAGER

  • MSDS: BWZTS
  • Manufacturer: MULTIGRAPHICS
  • Product Name: ELECTROSTATIC 867 CLEANING FLUID, MASTER IMAGER
  • National Stock Number: 6850-01-395-4115
Product Identification

Product ID:ELECTROSTATIC 867 CLEANING FLUID, MASTER IMAGER
MSDS Date:05/01/1992
FSC:6850
NIIN:01-395-4115
MSDS Number: BWZTS

Responsible Party
MULTIGRAPHICS
1800 W CENTRAL ROAD
MT.PROSPECT, IL 60056-2293
US

Emergency Phone: 312-870-5121 (DAY) 398-1900 (NIGHT)

Info Phone: 312-870-5121/708-870-5087

Cage: 09177

Contractor
AM MULTIGRAPHICS DIV OF AM INTL INC
MOUNT PROSPECT, IL 60056-6048 US

Telephone: 847-375-1700

Cage: 09177

Ingredients

MINERAL SPIRITS

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: 100%

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE-IRRITANT TO EYE. SKIN-PROLONGED
CONTACT WILL CAUSE DEFATTING, DRYING AND/OR CRACKING. POSSIBLE
DERMATITIS..
Explanation of Carcinogenicity:NOT FOUND TO BE CARCINOGENIC.
Effects of Overexposure:INHALATION-INHALATION OF LARGE QUANTITIES OF
VAPORS MAY CAUSE DIZZINESS, HEADACHE, CNS DEPRESSION. INGESTION-MAY
CAUSE HEADACHE, NAUSEA, VOMITING, CNS DEPRESSION.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:EYES-IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES, CALL A
PHYSICIAN. SKIN-IMMEDIATELY FLUSH WITH WATER. IF IRRITATION
DEVELOPS, CALL A PHYSICIAN. INHALATION-IMMEDIATELY REMOVE VICTIM TO
FRESH AIR. CALL A PHYSICIAN. INGESTION-DO NOT INDUCE VOMITING.
IMMEDIATELY DRINK WATER TO DILUTE. CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:140F,60C
Lower Limits:0.6
Upper Limits:7.0
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, FOAM OR CARBON DIOXIDE.
Fire Fighting Procedures:WATER SPRAY SHOULD BE USED TO COOL FIRE
EXPOSED CONTAINERS AND/OR DISPERSE UNIGNITED VAPORS. USE NIOSH/MSHA
APPROVED POSITIVE PRESSURE SELF-CONTAINED BREATHINGS
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:REMOVE ANY IGNITION SOURCES. PICK UP WITH
INERT ABSORBENT.

Handling

Handling and Storage Precautions:STORE IN COOL, WELL VENTILATED AREA,
AWAY FROM IGNITION SOURCES.
Other Precautions:READ AND FOLLOW LABEL PRECAUTIONS. DO NOT REUSE
CONTAINER. FOR COMMERCIAL/INDUSTRIAL USE ONLY. KEEP FROM REACH OF
CHILDREN.

Exposure Controls

Respiratory Protection:IN HIGH VAPOR CONCENTRATIONS WEAR NIOSH/MSHA
APPROVED ORGANIC AVPOR RESPIRATOR.
Ventilation:NONE BEYOUND GOOD ROOM VENTILATION REQUIRED.
Protective Gloves:NITRILE FOR CLEANUP.
Eye Protection:OPTIONAL.
Other Protective Equipment:AN EYE WASH STATION IF SPLASHING IS A
POSSIBILITY.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:365-403F
Vapor Pres:10
Vapor Density:>5
Spec Gravity:0.77
pH:7
Evaporation Rate & Reference:LESS THAN 0.1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID, FAINT HYDROCARBON ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS, LIQUID CHLORINE, CONCENTRATED OXYGEN, HYPOCHLORITES.
Stability Condition to Avoid:HIGH HEAT, IGNITION SOURCES.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF AS HAZARDOUS WASTE IN A MANNER
APPROVED FOR THIS MATERIAL. DO NOT POUR DOWN A COMMON DRAIN.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.